Lumencor SPECTRA

8-channel Light Engine illumination for fluorescence microscopy (with excitation 380-750nm) from DAPI to Cy7

Lumencor SPECTRA

8-channel Light Engine illumination for fluorescence microscopy (with excitation 380-750nm) from DAPI to Cy7

SPECTRA is a Light Engine fluorescent light where you can quickly switch between 8 different wavelengths and get a total of 400-700mW / wavelength (best in class). SPECTRA uses patented Light Engine technology that delivers higher intensity than conventional LED lights over the entire spectrum 380nm – 750nm.

SPECTRA is controlled via PC either from the supplied SPECTRA GUI software or other software such as NIS-Elements or µManager. Ideal for minimizing phototoxicity and bleaching of fluorochromes. With double/triple filters in the microscope, the ability to switch between excitation wavelengths within 1ms is achieved. Ideal for optogenetics, electrophysiology or timelapse fluorescence applications without the need for external filter wheels.

SPECTRA can be controlled from the NIS Elements software via USB or TTL.

Light Engine lighting unit SPECTRA offers:

  • 8 different wavelengths (390, 440, 475, 510, 555, 575, 640 and 740)
  • Broad spectrum – covers UV (DAPI) to nIR region (Cy7)
  • Control via software

Easy to use

  • Easily connected directly to the microscope via a light guide
  • Instant on/off function – No heating or cooling required
  • Stable and repeatable – reliable and consistent results
  • Precise intensity control of selected wavelength range in 1% steps (0-100%) – no ND filters required
  • Excellent light dispersion across the field of view – stable and maintenance-free
  • Long lifetime – expected to exceed 25,000 hours of operation
  • No lamp replacements or consumables

Contact the product specialist:

Torgeir Dahlen
torgeir.dahlen@bergmanlabora.se
Tel: 08-625 18 01

Johan Sternemalm
johan.sternemalm@bergmanlabora.se
Tel: 031-10 54 40

Technical specification

Microscope connection: 3 mm Liquid Light Guide (LLG)

Wavelength: 8pcs Light Pipes (390, 440, 475, 510, 555, 575, 640 and 740 nm)

Control: on/off and intensity adjustment of individual Light Pipes via software (µManager, NIS-Elements, etc.) and 8-channel on/off via BNC (TTL/analog) (option)

https://lumencor.com/products/spectra-light-engine/

SPECTRA is a Light Engine fluorescent light where you can quickly switch between 8 different wavelengths and get a total of 400-700mW / wavelength (best in class). SPECTRA uses patented Light Engine technology that delivers higher intensity than conventional LED lights over the entire spectrum 380nm – 750nm.

SPECTRA is controlled via PC either from the supplied SPECTRA GUI software or other software such as NIS-Elements or µManager. Ideal for minimizing phototoxicity and bleaching of fluorochromes. With double/triple filters in the microscope, the ability to switch between excitation wavelengths within 1ms is achieved. Ideal for optogenetics, electrophysiology or timelapse fluorescence applications without the need for external filter wheels.

SPECTRA can be controlled from the NIS Elements software via USB or TTL.

Light Engine lighting unit SPECTRA offers:

  • 8 different wavelengths (390, 440, 475, 510, 555, 575, 640 and 740)
  • Broad spectrum – covers UV (DAPI) to nIR region (Cy7)
  • Control via software

Easy to use

  • Easily connected directly to the microscope via a light guide
  • Instant on/off function – No heating or cooling required
  • Stable and repeatable – reliable and consistent results
  • Precise intensity control of selected wavelength range in 1% steps (0-100%) – no ND filters required
  • Excellent light dispersion across the field of view – stable and maintenance-free
  • Long lifetime – expected to exceed 25,000 hours of operation
  • No lamp replacements or consumables

Contact the product specialist:

Torgeir Dahlen
torgeir.dahlen@bergmanlabora.se
Tel: 08-625 18 01

Johan Sternemalm
johan.sternemalm@bergmanlabora.se
Tel: 031-10 54 40

Technical specification

Microscope connection: 3 mm Liquid Light Guide (LLG)

Wavelength: 8pcs Light Pipes (390, 440, 475, 510, 555, 575, 640 and 740 nm)

Control: on/off and intensity adjustment of individual Light Pipes via software (µManager, NIS-Elements, etc.) and 8-channel on/off via BNC (TTL/analog) (option)

https://lumencor.com/products/spectra-light-engine/

Need help choosing the right product?