Tillbaka

Ion-selective Electrodes

The use of ion-selective electrodes constitutes a quick and cost-effective method of determining ionic activity.Due to their quality and diversity, Radiometer Analytical ion-selective electrodes efficiently solve various analytical problems of species in solution.Each electrode is carefully checked before packing and is delivered with an individual control report including information such as the response curve, checkpoint value and slope.

Radiometer Ion-selective Electrodes

Ion Species Br - Ca ++  Cl - Cl -
         
Model  ISE25Br  ISE25Ca  ISE25Cl  ISE/HS25Cl 
Probe part no.  E41M001* E41M002*  E41M003*  E41M004* 
Combination probe 



Concentration range (M)  10 -6 -100  2 x 10 -6 -100  5 x 10 -5 -100  10 -6 -100 
Concentration range 



(ppm)  0.08 -80000  0.1 -40000  1.8 -35000  0.04 -35000 
Temperature range  0 -60°C  0 -50°C  0 -60°C  0 -60°C 
Diameter  12 mm  12 mm  12 mm  12 mm 
pH range  2 -14  4 -12  2 -14  2 -4 
Sensor type  Solid-state  PVC membrane  Solid-state  Solid-state 
Interfering ions  I -, S2-, CN -, SCN ­ Zn2+, Pb2+  I -, CN -, Br -, SCN ­ I -, CN -, Br -, SCN ­
Recommended reference electrodes  REF251  REF201 REF251 REF251 REF251


Ion Species CN -­ Cu ++  F -
   
   
Model  ISE25CN  ISE25Cu  ISE25F 
Probe part no.  E41M005*  E41M006*  E41M007*
Combination probe 


Concentration range (M)  5 x 10 -7 -10 -3  10 -6 -100  5 x 10 -7 -100 
Concentration range 


(ppm)  0.013 -25  0.06 -60000  0.01 -20000 
Temperature range  0 -60°C  0 -60°C  0 -60°C 
Diameter  12 mm  12 mm  7 mm 
pH range  9 -14  0 -14  5 -11 
Sensor type  Solid-state  Solid-state  Solid-state 
Interfering ions  I -, Br -, S2­ HgS, Ag+, Cl ­ OH ­
Recommended reference electrodes  REF201 REF251 REF201 REF251 REF201 REF25

*Screw cap electrode. Requires CL111 connection cable (part no. A94L111) for sensION+ meter compatibility

Radiometer Ion-selective Electrodes

Ion Species F - I - K+ 
     
 
Model  ISEC301F  ISE25I  ISE25K 
Probe part no.  E41M017* E41M008*  E41M009* 
Combination probe 


Concentration range (M)  5 x 10 -7 -100  10 -6 -10 -1  2 x 10 -6 -100 
Concentration range 


(ppm)  0.01 -20000  0.13 -13000  0.08 -40000 
Temperature range  0 -50°C  0 -60°C  0 -50°C 
Diameter  12 mm  12 mm  12 mm 
pH range  5 -7  2 -12  2 -12 
Sensor type  Solid-state  Solid-state  PVC membrane 
Interfering ions  OH ­ CN -, Hg2+, Br -, SCN ­ NH4 +, Rb+ 
Recommended reference electrodes  - REF201 REF251 REF201 REF251


Ion Species Na+  NH4 +  NO3 - Pb++ 
         
Model  ISE21Na  ISE25NH4  ISE25NO3  ISE25Pb 
Probe part no.  E41M010* E41M013*  E41M014*  E41M015* 
Combination probe 



Concentration range (M)  2 x 10 -6 -100  3 x 10 -6 -100  3 x 10 -6 -100  10 -6 -100 
Concentration range 



(ppm)  0.04 -20000  0.06 -20000  0.2 -60000  0.2 -200000 
Temperature range  0 -70°C  0 -50°C  0 -50°C  0 -60°C 
Diameter  12 mm  12 mm  12 mm  12 mm 
pH range  5 -12  3 -8  3 -10  3 -7 
Sensor type  Glass  PVC membrane  PVC membrane  Solid-state 
Interfering ions  Li+, NH4 +, Rb+, Ag+  K+  Cl -, Br -, NO2 - Hg2+, Cu2+, Ag+ 
Recommended reference electrodes  REF251 REF251 REF201 REF251 REF251

*Screw cap electrode. Requires CL111 connection cable (part no. A94L111) for sensION+ meter compatibility